SM1-PL-EOP-OX-FL

SM1-PL-EOP-OX-FL

SM1-PL-EOP-OX-FL

Quantity
  • Level of performance with AWAX controller: up to PL = e
  • Safety category: up to 4 with AWAX controller or PLC SIL 3
  • Time before dangerous failure: MTTFd = 100 years
  • Maximum detection activation distance: 2 mm
  • Holding force: up to 580 N
  • Safety contacts/diagnostics: 2 x NO 250mA max/24V redundant and
  • 1 x PNP 250mA
  • Detection encoding: mono-code inviolable
  • Indicator: LED
  • Reset: automatic or controlled (ref. + OP)
  • Attachment: 4 M4 screws (inviolable on new generation and optional ref.: BH4)
  • Mounting position: 1
  • Casing material: INOX316L mirror polished (OX version) or POLYCARBONATE (PL version)
  • Suction cup material: INOX (SM1 + OX) or steel (SM1 + PL-AC)
  • Electrical connection: the M12 metal base will be replaced with a 50cm PUR cord with an M12 connector on the new generation
  • Water resistance: IP 67/68 (OX version) / IP55 (Steel version)
  • Temperature: -25°C to +50°C.
  • Marking: laser engraving with mechanically punched serial number for permanent traceability (OX version) or screen printed serial number for traceability (PL version)

 