CW Process Instrumentation Store
		37, Jalan Bayu 7/6,
Nusa Bayu 79200,
Iskandar Puteri,
Johor, Malaysia.	
            
                  
	
			
  
- Temperature
 - Pressure
 - Humidity
 - Flow
 - Vibration
 - Ex-proof Intrinsically Safe
 - Level
 - Signal Converter & Signal Isolator
 - Paperless Recorder & Smart Process Indicator
 - Encorder & Linear Sensor
 - Load Cell Weighing Sensor & Weighing Indicator
 - Measurement & Control Device
 - Handheld Instruments
 - HMI (Human Machine Interface)
 - Genset Controller & Charger
 - Networking Switch
 - Industrial Power Supply
 - Inductive & Photo Sensor
 - Connecting Cable & Connector
 - Climate Control & Lighting
 - Electrical Component
 - Variables Speed Drives (Inverter) & Soft Starter
 - Industrial Control Panel
 - Batch Counter
 - CLASS 1 CT
 - Digital Indicator
 - Digital Voltmeter & Ammeter
 - Humidistats and condensation controllers
 - Humidity and Temperature Sensors
 - Humidity temperature sensor DWK
 - Limit Switch Box
 - Magnetic Pickup Sensor
 - PANEL MEASURING INSTRUMENTS
 - PLC
 - POWER Meter & kWH meter
 - Safety Modules / Safety Relays
 - Safety Switch & Safety Sensor
 - SENSOR
 - SIGNAL TRANSDUCERS
 - Transmitter for humidity and temperature DZK
 - Others
 
AWAX28XXLP
           
                
                
               | 
        
          AWAX28XXLP
              Quantity 
             
            
            
            
            
            
            
            
 AWAX 28XXL - SAFETY RELAYS - SELF CHECK BOX 
            
            
            
            
          Sensor controller on Acotom process / mechanical switches / emergency stops Safety management on 9 outputs in a compact 45mm housing Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 75 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant in serial (XXL version) or parallel (XXLP version) Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11  | 
      

                
                
              .png)